GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps

Wuhan Spico Machinery & Electronics Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps from wholesalers
     
    Buy cheap GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps from wholesalers
    • Buy cheap GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps from wholesalers
    • Buy cheap GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps from wholesalers
    • Buy cheap GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps from wholesalers

    GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps

    Ask Lasest Price
    Brand Name : Tornatech
    Certification : UL,FM
    Payment Terms : L/C, T/T
    Delivery Time : 35-40 Working Days
    Price : Negotiation
    Model Number : GPD-24-120/220
    • Product Details
    • Company Profile

    GPD series Tornatech Fire Pump Controller for Diesel Engine Fire Fighting Pumps

    UL/ FM Tornatech Controller For Fire Fighting Systems


    Diesel engine fire pump controllers are designed to automatically start a diesel engine driven fire pump upon
    detection of a pressure drop in the fire protection system. A diesel engine fire pump controller provides automatic &
    manual starting and stopping. An automatic start is controlled by a pressure transducer or by remote automatic
    devices as deluge valve. A manual start is controlled by remote manual button or by controller pushbutton. The
    automatic shutdown option provides a 30-minutes automatic stop after automatic start once all starting causes have
    returned to normal. The diesel engine fire pump controller includes two battery chargers to maintain the engine
    batteries continuously charged.



    Types of Diesel Engine Fire Pump Controllers


    METHODS OF STARTING


    AUTOMATIC START
    The controller will start automatically on low pressure detection by the pressure sensor when pressure drops below
    the cut-in threshold. The controller must be in automatic mode.
    MANUAL START
    The engine can be started by pressing the CRANK 1 or and/or CRANK 2 push button, regardless of the system
    pressure, when the Main Selector switch is in the HAND position. The Fuel Solenoid Valve will open as soon as a
    CRANK button is pressed and will remain in this state.
    REMOTE MANUAL START
    The engine can be started from a remote location by momentarily closing a contact of a manual push button.
    REMOTE AUTOMATIC START, DELUGE VALVE START
    The engine can be started from a remote location by momentarily opening a contact connected to an automatic
    device. The controller must be in automatic mode.
    SEQUENTIAL START
    In case of multiple pump application, it may be necessary to delay the starting of each motor in case of water
    pressure drop to prevent simultaneous starting of all motors.


    FLOW START, HIGH ZONE START
    The controller can be started by opening/closing a contact on the FLOW/ZONE START/STOP input.
    WEEKLY START
    The engine can be started (and stopped) automatically at the preprogrammed time.
    TEST START
    The motor can be started automatically for a preprogrammed time by pressing the run test button.


    METHODS OF STOPPING


    MANUAL STOP
    Manual stop is done by pressing the STOP push button. Note that pressing the stop push button will stop the
    engine only if all starting causes have disappeared.
    AUTOMATIC STOP
    The automatic stop is possible only after an automatic start and this function must be activated. When this function
    is enabled, the motor is automatically stopped 30 minutes after the restoration of the pressure (above the cut-out
    threshold) given that no other run cause is present.
    FLOW STOP, HIGH ZONE STOP
    If the controller has been started by the FLOW/ZONE START/STOP input and that the signal has returned to
    normal, the motor will be stopped given that no other run cause is present.
    EMERGENCY STOP
    The emergency stop is always possible in any running condition and is done by positioning the main selector switch
    to the OFF position.